Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 102(7): 1376-1385, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37727885

RESUMO

OBJECTIVES: The aim of the current study was to analyze the clinical and procedural predictors of thrombocytopenia and the relationship between the decrease in platelet count (DPC) and change in vWF function (ΔvWF) after transcatheter aortic valve replacement (TAVR). BACKGROUND: TAVR often causes temporary thrombocytopenia. At the same time, TAVR leads to a restoration of von Willebrand factor (vWF) function. METHODS: One hundred and forty-one patients with severe aortic stenosis undergoing TAVR were included in the study. Platelet count and vWF function (vWF:Ac/Ag ratio) were assessed at baseline and 6 h after TAVR. Thrombocytopenia was defined as platelet count <150/nL. RESULTS: Median platelet count at baseline was 214/nL (interquartile range [IQR]: 176-261) and decreased significantly to 184/nL (IQR: 145-222) 6 h after TAVR. The number of patients with thrombocytopenia increased from 12.8% at baseline to 29.1% after 6 h. DPC 6 h after TAVR showed a significant correlation with ΔvWF (r = - 0.254, p = 0.002). Patients with DPC > 20% had significantly higher ΔvWF (10.9% vs. 6.5%, p = 0.021). Obese patients showed a significantly lower DPC (11.8% vs. 19.9%, p = 0.001). In multivariate analysis, ΔvWF 6 h after TAVR was the only significant predictor for DPC > 20% (p = 0.017). CONCLUSIONS: The restoration of vWF after TAVR is a significant predictor for DPC after TAVR. An increased platelet consumption due to vWF restoration could play a key role in the development of thrombocytopenia after TAVR.


Assuntos
Estenose da Valva Aórtica , Trombocitopenia , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Fator de von Willebrand , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Resultado do Tratamento , Fatores de Risco , Trombocitopenia/diagnóstico , Trombocitopenia/etiologia
2.
Clin Res Cardiol ; 111(12): 1348-1357, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35838799

RESUMO

BACKGROUND: Aortic stenosis (AS) can cause acquired von Willebrand syndrome (AVWS) and valve replacement has been shown to lead to von Willebrand factor (vWF) recovery. The aim of the current study was to investigate the prevalence of AVWS in different severe AS phenotypes and its course after transcatheter aortic valve implantation (TAVI). METHODS: 143 patients with severe AS undergoing TAVI were included in the study. vWF function was assessed at baseline, 6 and 24 h after TAVI. AVWS was defined as a reduced vWF:Ac/Ag ratio ≤ 0.7. Phenotypes were classified by tricuspid (TAV) and bicuspid (BAV) valve morphology, mean transvalvular gradient (Pmean), stroke volume index (SVI), ejection fraction (EF) and indexed effective orifice area (iEOA). RESULTS: AVWS was present in 36 (25.2%) patients before TAVI. vWF:Ac/Ag ratio was significantly lower in high gradient compared to low-gradient severe AS [0.78 (IQR 0.67-0.86) vs. 0.83 (IQR 0.74-0.93), p < 0.05] and in patients with BAV compared to TAV [0.70 (IQR 0.63-0.78) vs. 0.81 (IQR 0.71-0.89), p < 0.05]. Normalization of vWF:Ac/Ag ratio was achieved in 61% patients 24 h after TAVI. As in the overall study cohort, vWF:Ac/Ag ratio increased significantly in all severe AS subgroups 6 h after TAVI (each p < 0.05). Regarding binary logistic regression analysis, BAV was the only significant predictor for AVWS. CONCLUSIONS: BAV morphology is a strong predictor for AVWS in severe AS. TAVI restores vWF function in most patients with severe AS independently of AS phenotype and valve morphology.


Assuntos
Estenose da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Substituição da Valva Aórtica Transcateter , Doenças de von Willebrand , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Fator de von Willebrand , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Doenças de von Willebrand/etiologia , Doenças de von Willebrand/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...